The AME-PVM-2L double planetary vacuum mixer combines low-speed mixing under vacuum with high-speed dispersion. It is intended for mixing solvents and powders in raw-material preparation processes, including those for lithium-ion batteries, solar energy, adhesive tape, and chemicals.
· Planetary mixing uses twisted-frame mixing paddles, high-speed dispersing discs, and wall scraping to reduce unmixed areas.
· Vacuum operation removes bubbles generated during mixing and provides vacuum retention.
· Low-speed revolution and self-rotation provide bulk mixing; the high-speed dispersing disc provides shear for fine mixing.
· Multi-stage speed operation allows the mixing speed and duration of each stage to be set.
· The mixing vessel has a 2L effective capacity and is made of SUS304 stainless steel for resistance to acid and alkali corrosion.
· A spotlight aids operation and safety during vacuum mixing.
· The jacketed mixing vessel accepts cooling water for different process requirements.
· PLC control and HMI operation are available; the specified Delta PLC and Weintek touchscreen configuration is listed as optional below.
The photographs and dimensioned views below show the supplied equipment configuration; the delivered unit governs final appearance.
Mixing paddle and vessel detail
Front and side dimensional views
|
Parameter |
Specification |
|
Body structure |
Crossbeam cantilever structure |
|
Power supply |
Single-phase, 220V; total power 3kw |
|
Mixing motor power |
0.75Kw |
|
Dispersion motor power |
1.5Kw |
|
Maximum revolution speed |
70rpm |
|
Maximum mixing self-rotation speed |
112rpm |
|
Maximum dispersion speed |
3850rpm; maximum linear speed 9.47m/s; dispersing disc diameter D47mm |
|
Vacuum system |
Vacuum buffer tank and switch, with vacuum pump; vacuum level -0.098Mpa |
|
Mixing configuration |
Revolution plus self-rotation; dual mixing shafts + dual dispersing shafts + one wall scraper |
|
Temperature measurement |
Vessel wall measurement |
|
Lifting system |
Manual lifting |
|
Sealing materials |
Static seals: silicone rubber / fluororubber / nitrile rubber; dynamic seal: SiC-S + fluororubber |
|
Control cabinet |
Variable-frequency speed control, temperature control, spotlight, lifting, run/emergency-stop display and operation on the cabinet control panel. Optional: Taiwan Delta PLC and Taiwan Weintek touchscreen for timed automatic variable-speed operation. |
|
Mixing vessel |
Dia. 180mm* H.130mm; effective capacity 2L; design capacity 3L; two handles |
|
Insulation |
Cooling-water temperature reduction; no insulation required |
|
Mixing paddles |
Twisted-frame type, one-piece cast, precision-machined and polished. Paddle-to-bottom clearance: 2~4 mm; paddle-to-vessel-wall clearance: 2~5 mm; paddle-to-paddle clearance: 3~10 mm. |
|
Wall-scraper paddle |
Teflon material; 304 support and scraper; quantity: 1 |
|
Overall dimensions (L x W x H) |
900 x 750 x 1700mm |
|
Weight |
450Kg |
|
Other supplied details |
Interface, labels, and printing can be customized as requested. Plywood case with pallet base for export packing and environmentally friendly pearl-cotton filling. One manual scraper is supplied. |
|
Part |
Material |
|
Upper vessel body |
SUS304 |
|
Lower vessel body |
SUS304 |
|
Jacket |
SUS304 |
|
Mixing and dispersion shafts |
SUS304 |
|
Mixing paddles |
SUS304 |
|
Frame and base |
Q235A |
|
Connection |
Specification |
Quantity |
|
Powder feed port |
DN50, quick-opening |
1 |
|
Discharge port (vessel side) |
1" plunger valve |
1 |
|
Sight glass |
DN50 |
2 |
|
Vacuum port |
G1/2", ball valve |
1 |
|
Air vent |
G1/2", ball valve |
1 |
|
Vacuum gauge port |
M14X1.5 |
1 |
|
Cooling-water ports |
G1/2" |
1 inlet and 1 outlet |
1. Pressing the emergency stop switch stops the equipment immediately.
2. The motor and frequency converter have overcurrent and overload protection.
3. An interlock permits mixing to start only after the upper and lower vessel sections are closed.
|
Accessory |
Quantity / purpose |
|
Sealing-ring set |
1 set, for the vessel body and lid |
|
Synchronous belt |
1 set |
|
Three-core cable |
1 piece, 5M |
1. Operating manual
2. Danfoss frequency-converter manual
3. Packing list
|
Component |
Brand |
|
Frequency converter |
Danfoss |
|
Motor |
Siemens |
|
Reducer |
Yongkun |
|
PLC (optional configuration) |
Delta |
|
Touchscreen (optional configuration) |
Weintek |
|
Main electrical components |
Schneider (France) / Huibang |
|
Switching power supply |
Mean Well |
|
High-speed bearings |
NSK (Japan) |
|
Drive belt |
Luodi |
|
Gears |
Shaoguan Gear |
|
Vacuum pump |
Feiyue |
1. Wipe the machine regularly with a soft cloth moistened with alcohol to keep it clean.
2. Lubricate moving parts to maintain smooth movement.
3. If the machine will not be used for a long period, clean the surfaces of moving parts and apply rust-preventive oil.
4. Periodically inspect screws, nuts, pins, and other fasteners to prevent loosening and avoid equipment or personal accidents.
1. During operation, do not place hands or any other body part in moving parts or hazardous working areas. Do not allow two or more people to operate the machine at the same time, to avoid accidental injury.
2. Only technical personnel or designated personnel may disassemble the equipment.