AME-HC25-32 Mini All-in-One Testing System

1. Product model

1. 1 Material code

WHW-25L+15C-5V100mA-32CH

 1.2 Equipment appearance

The    picture    is    for

reference only, subject

to the actual product

 

2. Product application

Application scenarios

Constant temperature test of snap-on cells

3. Sample restrictions

 

This test equipment is prohibited:

Test or storage of samples of inflammable, explosive and volatile substances Testing or storage of corrosive material samples

Test or storage of samples from strong electromagnetic sources Testing and storage of radioactive material samples

Testing and storage of samples of highly toxic substances

Tests or storage of samples ofthe above substances or objects during testing or storage

4.  Volume, size and weight

4. 1 Nominal volume

25L

4.2 Inner box size

W360 mm×D300 mm×H200 mm

4.3 External dimensions

W440 mm×D550 mm×H390 mm

4.4 Weight

About 50kg

5. Performance

5. 1 Test environment conditions

The ambient temperature is +25℃, the relative humidity is less than or equal to 85%, and there is no sample in the test chamber (no load)

5.2 Test method

GB/T 5170.2-2017 Temperature test equipment

5.3 Temperature range

15~60℃

5.4 Temperature fluctuation

 

≤±0.5℃ (no load, temperature stable)

5.5 Temperature deviation

±2.0℃ (no load, temperature stable)

5.6 Heating time

25℃→60℃ ≤50 min (no load, average nonlinearity)

5.7 Cooling time

25℃→ 15℃ ≤60 min (no load, average nonlinearity)

6. Structural characteristics

 6. 1 Insulation envelope structure

Exterior wall material: high quality cold rolled steel plate, surface spray treatment

Inner wall material: stainless steel plate SUS304

Box insulation material: polyurethane foam

6.2 Air conditioning channel

 

DC fan, semiconductor cooling (heating) module

 6.3 Standard configuration of test chamber

Door: hollow tempered glass + frame Cell fixture connection plate: 2 pieces Lighting: LED lighting

6.4 Control panel

Touch control button

6.5 Air conditioning unit

Semiconductor cooling (heating) module

7. Electrical control system

7. 1 Controller

LED digital display + touch key controller

7.2 Setting method

Touch-key type

 7.3 Control mode

The forced circulating ventilation is controlled by the control system according to the set temperature value through PID automatic calculation output results to control the output of the semiconductor cooling (heating) module, so as to achieve dynamic balance

7.4 Communication mode

Ethernet standard interface

8. Cell testing equipment and test interconnection

8. 1 Testing equipment

5V100mA32CH

8.2 Control unit

1

8.3 Network switch

1

 8.4 Network diagram

INQUIRE