1. Product model |
||
|
1. 1 Material code |
WHW-25L+15C-5V100mA-32CH |
|
|
1.2 Equipment appearance |
The picture is for reference only, subject to the actual product |
|
|
2. Product application |
||
|
Application scenarios |
Constant temperature test of snap-on cells |
|
|
3. Sample restrictions |
||
|
|
This test equipment is prohibited: Test or storage of samples of inflammable, explosive and volatile substances Testing or storage of corrosive material samples Test or storage of samples from strong electromagnetic sources Testing and storage of radioactive material samples Testing and storage of samples of highly toxic substances Tests or storage of samples ofthe above substances or objects during testing or storage |
|
|
4. Volume, size and weight |
||
|
4. 1 Nominal volume |
25L |
|
|
4.2 Inner box size |
W360 mm×D300 mm×H200 mm |
|
|
4.3 External dimensions |
W440 mm×D550 mm×H390 mm |
|
|
4.4 Weight |
About 50kg |
|
|
5. Performance |
||
|
5. 1 Test environment conditions |
The ambient temperature is +25℃, the relative humidity is less than or equal to 85%, and there is no sample in the test chamber (no load) |
|
|
5.2 Test method |
GB/T 5170.2-2017 Temperature test equipment |
|
|
5.3 Temperature range |
15~60℃ |
|
|
5.4 Temperature fluctuation |
≤±0.5℃ (no load, temperature stable) |
|
|
5.5 Temperature deviation |
±2.0℃ (no load, temperature stable) |
|
|
5.6 Heating time |
25℃→60℃ ≤50 min (no load, average nonlinearity) |
|
5.7 Cooling time |
25℃→ 15℃ ≤60 min (no load, average nonlinearity) |
|
6. Structural characteristics |
|
|
6. 1 Insulation envelope structure |
Exterior wall material: high quality cold rolled steel plate, surface spray treatment Inner wall material: stainless steel plate SUS304 Box insulation material: polyurethane foam |
|
6.2 Air conditioning channel |
DC fan, semiconductor cooling (heating) module |
|
6.3 Standard configuration of test chamber |
Door: hollow tempered glass + frame Cell fixture connection plate: 2 pieces Lighting: LED lighting |
|
6.4 Control panel |
Touch control button |
|
6.5 Air conditioning unit |
Semiconductor cooling (heating) module |
|
7. Electrical control system |
|
|
7. 1 Controller |
LED digital display + touch key controller |
|
7.2 Setting method |
Touch-key type |
|
7.3 Control mode |
The forced circulating ventilation is controlled by the control system according to the set temperature value through PID automatic calculation output results to control the output of the semiconductor cooling (heating) module, so as to achieve dynamic balance |
|
7.4 Communication mode |
Ethernet standard interface |
|
8. Cell testing equipment and test interconnection |
|
|
8. 1 Testing equipment |
5V100mA32CH |
|
8.2 Control unit |
1 |
|
8.3 Network switch |
1 |
|
8.4 Network diagram |
|